Texas Commission on Environmental Quality
Complying with the Edwards Aquifer Rules — Technical Guidance on Best Management Practices
Document Metadata
“The Edwards Aquifer rules are an effective mechanism we can use to protect this valuable resource. Found in Title 30 Texas Administrative Code Chapter 213”
Preface
“Texas Commission on Environmental Quality”
Title Page
“RG-348 Revised July 2005 Includes Errata Sheet (March 28, 2009) and Addendum Sheet (Jan. 20, 2017).”
Title Page
“Revised July 2005”
Title Page
“Addendum Sheet (Jan. 20, 2017).”
Title Page
“The Edwards Aquifer Rules (30 TAC Chapter 213) regulate activities having the potential for polluting the Edwards Aquifer”
Chapter 3.1
Design Criteria
“Structural BMPs located in the floodplain should be constructed with the wall elevation of any basins or ponds higher than the elevation of the 100 year flood at that location.”
Chapter 3.1
“The selected BMP or combination of BMPs must reduce the increase in total suspended solids (TSS) load associated with development by at least 80%.”
Chapter 3.1
“The runoff rate from the tributary area is calculated using the rational method as shown in Equation 3.4.”
Section 3.3.2
No evidence cited
“Retention/Irrigation 100 ... Extended Detention Basin 75 ... Grassy Swales 70 ... Vegetative Filter Strips 85 ... Sand Filter Systems 89 ... Bioretention 89 ... Wet Basins 93 ... Constructed Wetlands 93 ... Permeable Concrete 89-100”
Table 3-1