Stormwater Atlas

City of Grand Prairie

iSWM Criteria Manual for Site Development and Construction

CityTexasmediumNeeds reviewCitations verified

This extraction is flagged for quality review.

Compare each cited field to the official PDF before relying on it. What this means

NCTCOG iSWM regional criteria — confirm city adoption / local amendments. Pipeline excerpt repair removed 1 unlocated citation(s).

Fields not found in document: document_metadata.jurisdiction_name

Document Metadata

Jurisdiction level
City

No evidence cited

State
Texas

No evidence cited

Version / edition
Revised January 2015

No evidence cited

Adoption / effective date
2015-01

No evidence cited

Last revised date
2015-01

No evidence cited

Relationship to state manual
adopts state manual directly

No evidence cited

Design Criteria

Design storm return periods (years)
1-year, 25-year, 100-year

No evidence cited

Water quality volume method
Water Quality Protection Volume (WQv) based on 1.5 inches of rainfall (85th percentile storm). Streambank Protection: control 1-year, 24-hour storm; Conveyance: 25-year; Flood Mitigation: 100-year.

No evidence cited

Peak flow calculation method(s)
Rational Method, SCS Unit Hydrograph Method, Streambank Protection Volume (SPV), 25-year conveyance / 100-year flood mitigation

No evidence cited

Hydrologic/hydraulic software
Not found in document

No evidence cited

Approved BMP categories
Bioretention, Enhanced swales, Detention, Sand filters / filter boxes, Infiltration wells and trenches

No evidence cited