City of Fort Worth
Stormwater Criteria Manual
This extraction is flagged for quality review.
Compare each cited field to the official PDF before relying on it. What this means
Fort Worth July 2024 SCM; WQ Option 2 is iSWM-aligned but City notes WQ not currently required by CFW itself. Pipeline excerpt repair removed 2 unlocated citation(s).
Document Metadata
“Adoption of Manual by City of Fort Worth”
Adoption
“TPDES Stormwater permit”
Design options table
No evidence cited
“This Stormwater Criteria Manual ("Manual") is adopted and becomes effective on July 15, 2024.”
Adoption
No evidence cited
“The North Central Texas Council of Government ("NCTCOG") iSWM Technical Manuals are adopted and incorporated herein by reference.”
Adoption
Design Criteria
“No increase greater than 0.1 feet in 1-, 5-, and 100-year flood elevations”
Flood criteria
“Treat the Water Quality Protection Volume (WQV) by reducing total suspended solids from the Development site for runoff resulting from rainfalls of up to 1.5 inches (85th percentile storm)”
Design Options / Water Quality
“Provide on-site controlled release of the 1- year, 24-hour storm event over a period of 24 hours (Streambank Protection Volume, SPV)”
Streambank Protection Option 3
No evidence cited
“Dry Detention Pond / Underground Detention”
Tables 3.22-3.23