Regional SWFWMD ERP Applicant's Handbook Vol II (Tampa Bay / SW Florida WMD), not a City of Tampa municipal manual. Source PDF appears draft (DRAFT/NEW DATE OCR artifacts and duplicated text). Numeric WQ depths also defer heavily to statewide AH Volume I; Vol II retains classic one-inch wet detention / half-inch retention-filtration-exfiltration sizing plus OFW +50%. Jurisdiction coded as county per task guidance.
Document Metadata
“This Volume II ... is intended for use only within the jurisdictional boundaries of the Southwest Florida Water Management District.”
Section 1.0 Introduction
“administration of Chapter 62-330, Florida Administrative Code (F.A.C.).”
Section 1.0 Introduction
“EFFECTIVE June 1, 2018NEW DATE”
Title Page
“EFFECTIVE June 1, 2018”
Title Page
“EFFECTIVE June 1, 2018”
Title Page
“Each Water Management District has adopted an ERP Applicant's Handbook Volume II ... District-specific design and performance criteria for stormwater quantity or, flood control systems, design criteria for stormwater quality systems”
Section 1.0 Introduction
Design Criteria
“off-site discharges and peak stages for the existing and developed conditions shall be computed using the Southwest Florida Water Management District's 24-hour, 25-year rainfall maps and the Natural Resources Conservation Service type II Florida Modified 24-hour rainfall distribution”
Section 3.1 Discharges
“The required water quality system must have treatment capacity for one inch of runoff if wet detention is used, or one-half inch of runoff if retention, effluent filtration or exfiltration is used, from the total developed site and contributing offsite area.”
Section 3.5 / water quality capacity
“historic discharge, which is the peak rate at which runoff leaves a parcel of land by gravity under existing site conditions, or the legally allowable discharge at the time of permit application”
Section 3.1.a
No evidence cited
“a. Wet Detention Systems ... b. Detention with Effluent Filtration System (Manmade Underdrains) ... c. On-line Treatment Systems ... d. Off-line Treatment Systems ... e. Underground Exfiltration Systems”
Part IV Table of Contents / Section 4.1