Design Criteria

Design storm return periods (years)
25-year, 100-year

No evidence cited

Water quality volume method
SFWMD ERP AH Vol II: wet detention volume for the first inch of runoff from the developed project (or 2.5 in over the basin for projects with ≥50% impervious / special cases per rule); dry detention = 75% of wet; retention = 50% of wet. Quantity: off-site discharge typically based on 3-day / 25-year storm unless local criteria are more stringent; 100-year / 3-day considered for flood protection / finished floors.

Wet detention volume shall be provided for the first inch of runoff

SFWMD Vol II water quality criteria

Peak flow calculation method(s)
3-day / 25-year off-site discharge (default), 100-year / 3-day flood considerations, Retention / detention routing

No evidence cited

Hydrologic/hydraulic software
Not found in document

No evidence cited

Approved BMP categories
Wet detention systems, Dry retention / detention, Exfiltration trenches, Swales / pretreatment, Other SFWMD-approved BMPs

No evidence cited