Drainage Manual for Public and Private Drainage Facilities — Division IV Private Storm Drainage Facilities Requirements

CityCaliforniamediumNeeds reviewCitations verified

This extraction is flagged for quality review.

Compare each cited field to the official PDF before relying on it. What this means

Anaheim Division IV only (10 pages). Full city criteria also in Div I–III adopting OC manuals with revisions — already have orange-county-ca LDM. Pipeline excerpt repair removed 2 unlocated citation(s).

Fields not found in document: document_metadata.adoption_or_effective_date, design_criteria.required_hydrologic_hydraulic_software, document_metadata.version_or_edition, document_metadata.last_revised_date

Document Metadata

Jurisdiction level
City

City of Anaheim

Title

State
California

Santa Ana River

Section 1

Version / edition
Not found in document

No evidence cited

Adoption / effective date
Not found in document

No evidence cited

Last revised date
Not found in document

No evidence cited

Relationship to state manual
independent

PRIVATE STORM DRAINAGE FACILITIES REQUIREMENTS

Division IV

Design Criteria

Design storm return periods (years)
10-year, 25-year, 100-year

minimum of the 10-year storm / capture Q25 / 100-year protection of habitable areas

Section 1 Design Criteria

Water quality volume method
City adopts Orange County Hydrology Manual and Local Drainage Manual with Anaheim revisions (other divisions). This Division IV covers private facility design criteria; sump inlets designed for Q25 with 100-year habitable-area protection if grate fully clogs.

special drainage design requirements for private storm drains

Section 1

Peak flow calculation method(s)
Private drains tributary to Santa Ana River (not connected to public facilities): minimum 10-year recurrence interval, Onsite sump grate inlets designed to capture Q25, 100-year protection of habitable areas with emergency overflow / freeboard if grate clogs 100%

Onsite inlets in sump condition shall be designed to capture Q25

Section 1.D

Hydrologic/hydraulic software
Not found in document

No evidence cited

Approved BMP categories
Private storm drains, Grate inlets / sump systems, Emergency overflow conveyance

Grate inlets are allowed on private property