Stormwater Atlas

City of Wilmington

NCDEQ Stormwater Design Manual (City Comprehensive Stormwater Ordinance / coastal MS4)

CityDEP / DEQNorth CarolinamediumNeeds reviewCitations verified

This extraction is flagged for quality review.

Compare each cited field to the official PDF before relying on it. What this means

Municipality coverage via NCDEQ Design Manual MDC (same pattern as Cary). City coastal ordinance may impose additional SA/ORW depths not fully extracted here. Pipeline excerpt repair removed 1 unlocated citation(s).

Fields not found in document: document_metadata.jurisdiction_name

Document Metadata

Jurisdiction level
City

No evidence cited

State
North Carolina

No evidence cited

Version / edition
Revised: 1-3-2017 (MDC chapter)

No evidence cited

Adoption / effective date
2017-01-03

No evidence cited

Last revised date
2017-01-03

No evidence cited

Relationship to state manual
adopts state manual directly

--- page 2 --- NCDEQ Stormwater BMP Manual ________________________________________________________________________________________________________ C-0. MDC for all SCMs 2 Revised: 1-3-2017 GENERAL MDC 1. SIZING. The design volume of SCMs shall take into

p. 2

Design Criteria

Design storm return periods (years)
10-year

No evidence cited

Water quality volume method
Wilmington stormwater permitting relies on NCDEQ Stormwater Design Manual Minimum Design Criteria. Combined SCM design volume must handle the required storm depth for the applicable program (often 1" for runoff treatment under 15A NCAC 02H .1021(6) for non-coastal HQW/ORW; coastal/SA waters follow applicable rule depths). Design volume based on build-out runoff from surfaces draining to the system.

combined design volume of all SCMs ... required storm depth ... one inch

NCDEQ C-0 GENERAL MDC 1

Peak flow calculation method(s)
NCDEQ MDC outlet erosion protection for 10-year peak, City Comprehensive Stormwater Ordinance criteria

No evidence cited

Hydrologic/hydraulic software
Not found in document

No evidence cited

Approved BMP categories
Infiltration systems, Bioretention cells, Permeable pavement, Vegetated swales, Level spreader-filter strips, SCM devices per 15A NCAC 02H .1051–.1062

No evidence cited