Compare each cited field to the official PDF before relying on it. What this means
Mesa EDS 2022 Ch 8; confirm retention depth/volume numeric criteria from Section 806 tables. Pipeline excerpt repair removed 2 unlocated citation(s).
Fields not found in document: document_metadata.adoption_or_effective_date, design_criteria.design_storm_return_periods_years, design_criteria.required_hydrologic_hydraulic_software, document_metadata.version_or_edition, document_metadata.last_revised_date
Document Metadata
Jurisdiction level
City
“City of Mesa”
Title
State
Arizona
“City of Mesa”
Title
Version / edition
Not found in document
No evidence cited
Adoption / effective date
Not found in document
No evidence cited
Last revised date
Not found in document
No evidence cited
Relationship to state manual
independent
“Engineering & Design Standards”
Purpose
Design Criteria
Design storm return periods (years)
Not found in document
No evidence cited
Water quality volume method
Chapter 8 Storm Water Drainage & Retention: on-site stormwater management and retention basin requirements. LID landscape guidance in Section 1112. Mesa LID Toolkit referenced as guideline.
“Section 806 - On-Site Storm Water Management”
Chapter 8
Peak flow calculation method(s)
On-site storm water management per Section 806, Street drainage and off-site storm water management per Section 807, Developed-condition runoff C coefficients by storm frequency (Table 8.1), Public and private retention basins (Sections 808–809)
“Table 8.1 - Developed Condition Runoff (C) Coefficients by Storm Frequency”
Chapter 8
Hydrologic/hydraulic software
Not found in document
No evidence cited
Approved BMP categories
Retention basins, Storm drains, Low Impact Development (LID) landscape features
“Retention Basins / Low Impact Development (LID) Landscape”
Sections 808 / 1112